Boiler akgv 17.4 borinskoe bus sit passport. Heating systems for country and country houses

Or contact our consultants.

Gas boiler (apparatus) "Borinskoye" AKGV - 17.4 (M) Eurosit - an economical and inexpensive device for heating and hot water supply, atmospheric stainless steel burner, piezo ignition, steel heat exchanger, copper DHW circuit, automation unit, security devices, energy independence , natural gas, floor installation.

AKGV (Combined Gas Water Heating Unit) is a double-circuit, provides heating of the coolant by combustion natural gas, if necessary, can be rebuilt for liquefied gas (check with specialists). Gas AKGV are used for heating and hot water supply of residential and industrial facilities (including large areas) with a water heating system, they are economical, easy to use and have a long service life.

The device AKGV - 17.4 (M) Eurosit is similar in design to a gas heating boiler, but simpler and cheaper. AKGV is an electrically independent device, equipped with an atmospheric gas burner Polidoro (Italy), safety devices (in case of flame failure, chimney failure, increased gas pressure, etc.). A tubular steel heat exchanger for heating provides efficient heating of the coolant and high efficiency unit. The heat exchanger of the DHW circuit is made of copper. Thanks to a well-thought-out design, the Borinsky AKGV boiler is reliable and durable, not capricious in operation, including with gas pressure drops, easy to operate - automatic and manual settings.
Borin gas boilers AKGV have a compact body of strict design for floor mounting, equipped with Eurosit or Minisit (Italy) gas automation system.

Apparatuses marked "M" have connecting dimensions similar to ZhMZ boilers and are suitable for their replacement.

Warranty period - 3 years
Country of origin AKGV - 17.4 (M) Eurosit - Russia

  • double-circuit apparatus
  • steel primary heat exchanger
  • copper DHW heat exchanger
  • atmospheric burner made of stainless steel
  • piezo ignition
  • gas control unit
  • security devices
  • energy independence
  • compact ergonomic body
  • floor mounting
  • Efficiency - 87%
  • Max. coolant temperature - 95°С

Got questions? Write, we will answer immediately!

Main characteristics

Power 17.4 kW

Dimensions 1050x403x463 mm

Mounting on the floor.

Ignition type piezo

The combustion chamber open

The weight 60 kg

Chimney diameter123 mm

Note. automation - Eurosit 630

contours 2

additional characteristics

Power 17.4 kW

Height 1050 mm

Width 403 mm

Depth 463 mm

The weight 60.0 kg

Mounting type floor

Guarantee period 3 years

Country of OriginRussia

Ignition type piezo

Heating area140 m2

The combustion chamber open

Availability of the display Not

Integrated pumpNot

Built-in boilerNot

Chimney diameter123 mm

Work on liquefied gasNot

Boiler Borinsk AKGV - 17.4 (M) "EUROSIT" copper DHW circuit equipped with modern automation and mounted on the floor. The model does not require an electrical connection, so it can be installed in almost any spacious room with maximum area up to 150 sq. meters. The equipment is capable of operating in several power levels.

Advantages of the heating boiler in question from the Borinsky trademark:

  • The heat exchanger is made of high quality material;
  • Open combustion chamber;
  • Ease of installation and maintenance;
  • Polymer staining;
  • maintainability;
  • Thermostat to prevent overheating of the heat exchanger;
  • Shutdown of gas supply in case of extinction (flame control);
  • Traction stabilizer for gusts of wind;
  • Low temperature of the lining of the apparatus;
  • Safety valve against overpressure.

Borinskoye boilers with a copper DHW circuit are non-volatile equipment, therefore they are safe and practical in operation. The devices are quickly installed and are suitable for use in complex configurations. The units have been designed for heating large buildings. Cases of all models are made of durable and corrosion-resistant steel.


Attention! boiler AKGV 17.4 double-circuit (copper DHW circuit) and is designed not only for heating, but also for hot water supply of your home. If you need a boiler only for heating, then you need to use a single-circuit analogue - boiler AOGV 17.4

Buying a gas boiler AKGV-17.4 made at the Russian plant in the Lipetsk region by skilled workers with a sober head and straight hands, you, first of all, get comfort and warmth for yourself and your family. The boilers of OAO Borinskoye do not leak or break because the management of the plant cares about the quality of its products and always complies with all standards and state standards in production.

AKGV 17.4-1- one of the most popular among inexpensive and most importantly reliable Russian boilers, for heating rooms ranging from 70 to 140.

The presence of a second circuit allows you to heat running water for use economic needs. At boiler temperature 70-80°Cheating occursat least 3.6 liters of water per minute at a temperature of 45 ° C

The boiler has a security system that works during:

    lack of gas or traction;

    water overheating;

    maintaining the set temperature;

Coppers with automatic equipment "SABK" are delivered only under the order. Always in the presence of boilers with automation SIT AKGV 17.4sit or AKGV 17.4 with a copper circuit.

Technical parameters of the boiler AKGV-17.4-1:

Manufacturer

OJSC "Borinskoye"

Guarantee period 36 months
Fuel Natural gas
Automation type sabk (Russia)
Rated thermal power automatic burner, kW (kcal/h) 17,4 (15000)
Heated area, m²
70...140
Natural gas pressure in front of the automation unit, Pa (mm water column)
- nominal 1274 (130)
- minimum 637 (65)
- maximum 1764 (180)
Volumetric content of carbon monoxide in dry undiluted natural gas combustion products, %, no more 0,05
Efficiency of the apparatus, % not less than 87
coolant Water GOST 2874-82
Heat carrier parameters, no more:
- absolute pressure, MPa 0,165
- maximum temperature, °C 95
- carbonate hardness, mg-eq/kg 0,7
- content of suspended solids is absent
Gas connection size:
- nominal diameter Du, mm 20
- thread according to GOST 6357-81 G ¾ - B
Water consumption in hot water supply mode when heated to 45°C, not less than, kg/min 3,7
Size of DHW coil fittings

DN 15, mm
G ½ - B

Nominal passage of water connecting pipes
- Du, mm
50
- thread according to GOST 6357-81, inch G 2 - B
Safety automation parameters
- gas supply to the main burner only if there is a flame on the pilot burner for a time, sec (no more)
60
- time to turn off the gas supply to the pilot and main burners, sec 10...60
Vacuum in the chimney behind the apparatus, Pa (mm water column)

2.94 to 29.4
(from 0.3 to 3.0)

Maximum excess pressure in the DHW system, MPa 0,6
Heat exchanger tank capacity, l 35,1
The maximum temperature of the combustion products leaving the chimney, ° C at a gas pressure of 180 mm of water. Art. 190
Machine weight, kg 65
Dimensions:
- width, mm
403
- depth, mm
463
- height, mm
994

Completeness of delivery

  • Boiler AKGV-17.4 assembled lined with foam in a cardboard box
  • Technical certificate
  • Certificate of conformity

PURPOSE

The device is intended for heat supply of residential premises and buildings for communal purposes, equipped with water heating systems with a water column height in the water circuit of not more than 6.5 m.
The device is designed for continuous operation on natural gas in accordance with GOST 5542-87.
The device is manufactured in UHL climatic version, category 4.2 according to GOST 15150-69.

Characteristics Safety Devices
  1. Connecting dimensions to the heating system correspond to "Zhukovsky"
  2. Special design of the heat exchanger, the use of high-quality material:
    a) durability;
    b) high efficiency;
    c) reliability.
  3. Stainless steel burner
  4. Optimum combustion chamber
  5. Temperature control
  6. Ease of installation and maintenance
  7. Polymer staining
  8. Reliability
  9. Maintainability
  10. Copper DHW circuit
  1. Temperature controller to prevent overheating of the heat exchanger
  2. Shutting off the gas supply in the event of a blackout (flame control)
  3. Shutdown in the absence of traction
  4. Wind traction stabilizer
  5. Low boiler lining temperature

 Operating manual for the gas boiler AKGV 17.4 Eurosit (see the connection diagram in this device passport)


SPECIFICATIONS

Parameter or dimension name Value
AKGV 11.6-1 AKGV 17.4-1 AKGV 23.2-1
1. Fuel Natural gas
2. Nominal pressure of natural gas in front of the automation unit, Pa (mm water column) 1274 (130)
Natural gas pressure range, mm.water column 65…180* 1
3. Volume content of carbon monoxide in dry undiluted natural gas combustion products, %, not more than 0,05
4. Efficiency of the device, % not less than 87
5. Coolant water
6. Coolant parameters, no more than:
0,1
- absolute pressure, MPa;
- maximum temperature, ºС 95
- carbonate hardness, mg-eq/kg, no more 0,7
- content of suspended solids is absent
7. Rated thermal power of the automatic burner, kW (kcal/h) 11,6 (10000) 17,4 (15000) 23,2 (20000)
8. Gas inlet size:
- nominal diameter Du, mm 15 20 20
G 1/2 -B G 3/4 -B G 3/4 -B
9. Safety automation parameters
60
- gas supply shutdown time for
pilot and main burners, sec
- when the gas supply is interrupted or there is no
flame on the pilot burner, no more
60
- in the absence of draft in the chimney, no more no less 10
10. Vacuum in the chimney behind the apparatus, Pa from 2.94 to 29.4
mm. water. Art. 0.3 to 3.0
11. Water consumption in hot water supply mode, not less than, kg/min
- when heated to 45°C 2,5 3,7 5,0
- when heated to 30°C 3,4 5,2 7,0
12. Size of DHW coil fittings Du - 15
G 1/2 - B
13. Maximum overpressure in the DHW system, MPa (kg/cm2) 0,6 (6)
14. Nominal passage of water connecting pipes Du, mm 40 50 50
- thread according to GOST 6357 - 81, inch G 1 1/2 -B G2-B G2-B
15. Mass of the device, kg, no more 45 50 55
16. Heated area, m 2, no more 90 140 190
17. Capacity of the heat exchanger tank, liter 39,7 37,7 35
18. The maximum temperature of the combustion products leaving the chimney, ° С (gas pressure 180 mm of water column) 130 160 210
*1 NOTE. The device is protected from emergency supply of inlet gas pressure up to 500 mm. water. Art. gas valve design.


DEVICE AND PRINCIPLE OF WORK.

The device consists of the following components and parts: a heat exchanger tank, a main burner, an ignition burner block with a thermocouple and an ignition electrode installed in it, a combined gas valve (multifunctional regulator), a draft stabilizer, lining parts.

In the upper part of the tank - heat exchanger, a temperature controller sensor is installed, connected by a capillary tube to the thermostatic valve actuator ("bellows - thermoballoon" system), and a thermometer sensor

The design feature of the 630 EUROSIT combined valve is the presence of a device for stabilizing the outlet gas pressure, as well as the combination of valve control in one handle with the designation of the positions by the corresponding symbols and numbers on its end face and the pointer on the valve cover. The dependence of the temperature of the heated water on the position of the control knob scale is shown below:

The principle of operation of the temperature controller is based on the expansion of the liquid when heated. The working fluid, heated in the sensor (thermoballoon) from the water in the heat exchanger tank heated by the combustion of natural gas, expands and flows through the capillary tube into the bellows, which converts the volumetric expansion into a linear movement of the mechanism that drives the system of two valves (instantaneous and metering ). The design of the mechanism provides protection against thermal overload, which protects the "bellows - thermal bulb" system from damage and depressurization.

  1. When setting the desired water temperature in the apparatus with the control knob to increase, the instantaneous (click) valve first opens, then the dosing valve.
  2. When the water temperature in the device reaches the set value, the dosing valve is smoothly closed, switching the main burner to the "small gas" mode.
  3. When the temperature rises above the set value, an instantaneous (click) valve is activated, completely shutting off the gas to the main burner.
  4. In the absence of draft in the chimney, the exhaust gases from the furnace heat the draft sensor, the sensor is triggered by opening the normally closed contacts of the thermocouple circuit. The electromagnetic (inlet) valve closes and shuts off gas access to the main and pilot burners. The draft sensor is designed to operate during the absence of thrust for at least 10 seconds.
  5. When the gas supply from the network is interrupted, the pilot burner instantly goes out, the thermocouple cools down, the electromagnetic valve closes, blocking the gas access to the main and pilot burners. When the gas supply is resumed, the passage through the apparatus is completely blocked.
  6. When the gas pressure in the network drops below 0.65 kPa, the gas pressure on the pilot burner will also drop, the thermocouple EMF will drop to a value insufficient to hold the valve. Solenoid valve will close and cut off the gas supply to the burners.

POSITIONING AND INSTALLATION

Placement and installation of the apparatus, as well as gas supply to it, is carried out by a specialized construction and installation organization according to a project agreed with the operating enterprise (trust) of the gas facilities.

The room where the device is installed must have free access of air from the outside and a ventilation hood near the ceiling.

The temperature of the room where the device is installed must not be lower than +5 ºС.

The choice of a place for the installation of the device should be made in accordance with the instructions for the safety measures set out in section 7 of this passport.

The device is installed near fireproof walls at a distance of at least 10 cm from the wall.

  1. When installing the apparatus near a fire-resistant wall, its surface must be insulated with a steel sheet over an asbestos sheet with a thickness of at least 3 mm, protruding 10 cm beyond the dimensions of the housing. There must be a passage at least 1 meter wide in front of the apparatus.
  2. When installing the apparatus on a combustible floor, the floor must be insulated with a steel sheet over an asbestos sheet with a thickness of at least 3 mm. The insulation should protrude 10 cm beyond the enclosure dimensions.

Before starting the installation, it is necessary to depreserve the device, check the correctness of its assembly in accordance with Fig. 1 and fig. 8 of this passport, and make sure that all parts and assembly units are securely and completely fixed.

Connect the device to the chimney, gas pipeline and pipes of the heating system. The connecting pipes of the pipelines must be exactly fitted to the location of the inlet fittings of the apparatus. Connection should not be accompanied by mutual tension of pipes and units of the apparatus.

SAFETY INSTRUCTIONS

Persons who have studied this passport are allowed to service the device.

The installation and operation of the apparatus must comply with the requirements of the Rules for the Design and Safety of Operation of Hot Water Boilers, Water Heaters and Steam Boilers with Overpressure, as well as the requirements of the Safety Rules for Gas Distribution and Gas Consumption Systems. PB 12 - 529", approved by the Gosgortekhnadzor of Russia.

The operation of the devices must be carried out in accordance with the "Rules fire safety for residential buildings, hotels, hostels, buildings of administrative institutions and individual garages PPB - 01 - 03.

The operation of the device is allowed only with serviceable automatic safety and thermal control.

Gas safety automatics should provide:

  1. Reducing the gas supply when the water temperature reaches heating system set value.
  2. Shutdown of gas supply to the main burner when the set heating temperature is exceeded.
  3. Turn off the gas supply to the device in the following cases:
    • when the gas supply to the apparatus is interrupted (for a time not exceeding 60 seconds);
    • in the absence of draft depression or in the boiler furnace (for a time not less than 10 seconds and not more than 60 seconds);
    • when the torch of the pilot burner goes out (for a time not exceeding 60 seconds).

During operation of the device, the temperature hot water must not exceed 95 °C.

It is forbidden:

  1. operate the device with the heating system partially filled with water;
  2. use other liquids as a heat carrier instead of water**;
  3. install shut-off and control valves on the supply line and the pipeline connecting the heating system with expansion tank;
  4. operate the device in case of gas leakage through the gas pipeline connections;
  5. use an open flame to detect gas leaks;
  6. operate the device in case of a malfunction of the gas network, chimney or automation;
  7. independently troubleshoot the device;
  8. make any structural changes to the apparatus, gas pipeline and heating system.

When the device is not working, all gas taps: in front of the burner and on the gas pipeline in front of the apparatus - must be in the closed position (the valve handle is perpendicular to the gas pipeline).

Any malfunctions during the operation of the apparatus on gas must be immediately reported to the emergency service of the operating enterprise of the gas economy.

If gas is found in a room, immediately stop its supply, ventilate all rooms and call an emergency or repair service. Until the malfunction is eliminated, it is forbidden to light matches in the room, smoke, use

** It is allowed to use household coolant "Olga" (manufacturer: CJSC "Plant of Organic Products") according to the instructions for use. After a period of operation, the coolant must be drained and disposed of.

Gas floor standing non-volatile boiler Angara-Lux - these are high-class boilers according to affordable price. Heating devices are reliable and durable. The heat exchanger in this series is made of 3 mm steel, has additional stiffening ribs and ties, which means that the service life of the heat exchanger increases by 15 years. The thickness of 3 mm allows the use of this unit in closed heating systems, the recommended working pressure is 2 atm.

Angara-Lux gas boilers are compact in size and light in weight, which allows them to be comfortably transported and installed in any premises.

The connecting pipes are located on three sides - thanks to this, the piping can be made on the left, right and behind the boiler.

Advantages of a gas boiler:

Angara-Lux gas boilers are equipped with digital temperature sensors;
the improved design of the chimney protects against blowing, and this affects efficiency.
boilers are economical and efficient - the efficiency of Angara-Lux boilers reaches 92%
can be used both in open and closed heating systems.
the service life of the gas boiler is at least 15 years.
The Angara-Lux gas boiler uses the Italian Sit automation unit. Automation Sit makes the boiler easy to operate, virtually silent and highly reliable. Also, the use of Sit automation allows the use of this boiler for bottled liquefied gas.

Specifications
BrandAngara Lux
Boiler typegas
Number of circuits double-circuit
The combustion chamberopen
Installationfloor
Heated area 170 sq. m.
Power17.4 kW
efficiency %92
Controlmechanical
Condensing Not
non-volatile Yes
Primary heat exchanger material steel
Consumption of liquefied gas, kg/h 1.34
Consumption of natural gas cube. m/hour 1.8
Nominal pressure of natural gas, mbar 6
Heat carrier temperature, °С 40 -
Hot water capacity at t 25°C, l/min 7.5
Max. water pressure in the heating circuit, bar 2
Comfort
Functionsthermometer
Security
Protectiongas control
Connection and overall dimensions
Chimney diameter 130 mm
The weight80 kg
Branch pipe for connecting the DHW circuit 1
Heating circuit connection 1"
Gas connection 1"

Floor standing gas boiler Angara Lux AKGV 17.4 reviews