Gas burners Ecoflam MAX GAS at a bargain price. Gas burners Ecoflam MAX GAS at a bargain price Gas burner ecoflam max gas 500
Burner Ecoflam (Ekoflam) MAX GAS 40 P TW TC for a heating boiler up to 40 kW. Thermowatt control unit. Ecoflam Max Gas models are available with a control unit, both Thermowatt and Siemens. The kit includes a connecting flange with a gasket and a seven-pin connector for connecting to automation. Single stage power control. Range: 17 - 48 kW. Short flame head TC, also available with long flame tube TL. The ramp is selected depending on the technical circumstances.
The line consists of branch pipes (threaded or flanged), electrical connections, a tap, if necessary, it can be equipped with a tightness control device (VPS) and an anti-vibration insert. The size and configuration of the gas train is determined from the operating conditions. This is influenced by the aerodynamic drag backpressure, the heat exchanger capacity, the incoming gas pressure in front of the valve, the type of regulation and much more.
Gas single-stage burner (with gas train)
Power: 34-70 kW,
Working gas pressure: 20 mbar.,
Ramp: GRRG100 (code 3123944) Model MB-DLE 403
Rail gas pressure (min/max) : 9/200 mbar
Distinctive features:
* Burner housing - aluminum alloy;
* Powerful HPV fan allows the burner to be operated with boilers with increased combustion chamber pressure;
* Low noise;
* Micrometric airflow adjustment system;
* The design of the burner is designed for Various types boilers with different standard sizes of the combustion chamber;
* Device for visual control of the flame;
single stage |
Power |
Gas consumption, |
||||||
Max |
Max |
|||||||
two stage |
Power |
Gas consumption, |
||||||
Max |
Max |
|||||||
ECOFLAM MAX GAS
Gas-burners ECOFLAM are designed to operate on gaseous fuels, have an aluminum housing, a powerful air blower and a protective housing to reduce noise. Thanks to the adjustable mixing kit, high burner performance and flame stability are achieved over the entire power range. The gas fittings include a working valve for adjusting the gas flow, a safety valve, a gas pressure filter, a minimum gas pressure switch. Burner equipment by ECOFLAM, Italy
Manufacturer Ecoflam
ECOFLAM was founded in 1973 in Castelfranco Veneto, in the northeast of Italy. Since 2005, the ECOFLAM brand has come under the control of the world's largest corporation ARISTON THERMO.
ECOFLAM are burners European quality in a convenient economical and energy-saving design. Equipped modern system security, are equipped with leading European manufacturers. ECOFLAM burners guarantee high performance and reliability combined with high efficiency. All models are characterized by exceptional ease of installation and maintenance, they are easily combined with any boiler.
Maximum power of ECOFLAM burners in model range is up to 25 MW.
All burners are designed and tested in our own research and development center "GREEN", are thoroughly tested and comply with EU standards and are ISO 9001 and VISION 2000 certified.
Ecoflam are burners of European quality in a convenient economical and energy-saving design. Equipped with a modern security system, completed by leading European manufacturers.
Burners "Ecoflam" guarantee high performance and reliability combined with great efficiency. All models are characterized by exceptional ease of installation and maintenance, they are easily combined with any type of boiler. Today, Ecoflam is a world-famous brand recognized for high equipment reliability and a flexible approach to individual problem solving for the most wide application in industry.
- Gas burners ECOFLAM Max Gas main characteristics
- Fully sealed aluminum housing in a modern design casing
- Compact burner dimensions combined with low noise level
- The fire burner is easy to install, its position is adjustable to ensure optimal compatibility of the burner with the boiler
- Powerful new generation fan (HPV) makes it possible to use the burner on boilers with increased back pressure in the combustion chamber
- To simplify maintenance, the burner is provided with a single mounting bolt, on which the burner can be hung by a special hook in various spatial positions.
- Ease of installation thanks to the adapter flange used, which is attached to the boiler and to which, in turn, the burner is connected (optional) Adapter size 60 or 80 mm for execution with external air intake (optional).
- Ease and speed of making electrical connections.
- The fire head is easy to assemble, its position is adjustable to ensure optimal compatibility of the burner with the boiler.
- To simplify maintenance, the burner has a single mounting bolt, on which the burner can be hung by a special hook in various spatial positions.
- Ease of installation due to the adapter flange used, which is attached to the boiler and to which, in turn, the burner is attached (optional).
- Servo air damper in two-stage burners.
- New Low NOx burners with low nitrogen oxide emissions, designed in the Ecoflam laboratories.
- A separate gas train (selected depending on the inlet gas pressure) is easily mounted on the burner body.
- High temperature version for industrial applications: kilns, dryers, special installations.
- Continuous ventilation in all models.
- Versions for BIOGAS and CITY GAS on request.
ECOFLAM Max Gas specifications
MODELS | Thermal power | Thermal power | Gas pressure | Power supply | Engine power | Modification | ||
kW | kcal/hour x 1000 | kW | kcal/hour x 1000 | mbar | AT | Tue | ||
MAX GAS 40 | 48 | 41,38 | 17 | 14,65 | 9 ? 200 | 230 | 50 | P |
MAX GAS 70 | 70 | 60,34 | 34 | 29,31 | 10 ? 360 | 230 | 50 | PA B |
MAX GAS 70 | 70 | 60,34 | 25 | 21,6 | 20 ? 300 | 230 | 50 | PAB/PR |
MAX GAS 105 | 108 | 96,10 | 49 | 42,24 | 13 ? 360 | 230 | 75 | P |
MAX GAS 105 | 108 | 96,10 | 40 | 34,48 | 13 ? 360 | 230 | 75 | PAB/PR |
MAX GAS 120 | 120 | 103,45 | 49 | 42,24 | 13 ? 360 | 230 | 75 | P |
MAX GAS 120 | 120 | 103,45 | 40 | 34,48 | 13 ? 360 | 230 | 75 | PAB/PR |
MAX GAS 170 | 175 | 150,86 | 55 | 47,41 | 12(14*) ? 360(500*) | 230 | 200 | P |
MAX GAS 170 | 175 | 150,86 | 55 | 47,41 | 12(14*) ? 360(500*) | 230 | 200 | PAB/PR |
MAX GAS 250 | 240 | 206,90 | 55 | 47,41 | 15(14*) ? 360(500*) | 230 | 200 | P |
MAX GAS 250 | 240 | 206,90 | 55 | 47,41 | 15(14*) ? 360(500*) | 230 | 200 | PAB/PR |
Fuel type: Natural gas (lower calorific value. 8.570 kcal/Nm3), liquefied gas (lower calorific value 22.260kcal/Nm3)
|
All MAX GAS burners are designed for natural gas and can run on liquefied propane
Conditions for replacing injectors with the appropriate set.
Two-stage MAX GAS burners models 120-250 are equipped with a gas multiblock
With MB-ZRDLE valves, while two-stage operation of models 350-500 is provided
Throttle valve.
MAX GAS 350-500 burners are also available in a sliding two-stage version, which
Converted to modulated using KITMD-RWF40 PID controller kit.
KIT - ACS (sets and accessories - see respective pages)
LPG Conversion Kit
Plug kit
PID controller and sensor kit
Anti-vibration insert and ball valve
Versions available on request:
CV: with constant ventilation
HT: high temperature version
OEM and special applications only on request
Execution according to EN676:
Gas multiblock Dungs: compact assembly of double solenoid valve with built-in filter, stabilizer
And a minimum pressure switch
VCS Kromschröder double solenoid valves with min pressure switch + separate pressure stabilizer and FGDR gas filter
Export version (other additional items must be ordered by the installer in accordance with local
safety regulations):
Double solenoid valves VCS Kromschröder: double solenoid valves with integrated min pressure switch
Gas multiblock Dungs GB-LE 055 class B: compact double solenoid valve and with built-in filter,
Stabilizer and minimum pressure switch for MAX GAS 40-120
Single solenoid valve Brahma E6G*SR P and EG12*L for MAX GAS 40-120 with min. gas pressure
Single solenoid valve Kromschröder VAS125 and VAS240 for MAX GAS 170-250 with min. gas pressure
< 80 мг/кВтˑч) - TW
G eagles | Power, kWt] | Burner body | Gas pressure [mbar] | gas train |
Stab. pressure and filter |
||||||
min | Max |
head |
the code | min | Max | the code | type | Ø | |||
MAX GAS 40 P TW | 17 | 48 | TC | 3142741 | 9 | 65 | 3141885 | MBC 65 DLE | 1/2" | included | |
9 | 200 | 3123944 | MB-DLE 403 | ||||||||
TL | 3142742 | 9 | 65 | 3141885 | MBC 65 DLE | 1/2" | included | ||||
9 | 200 | 3123944 | MB-DLE 403 | ||||||||
MAX GAS 70 P TW | 34 | 70 | TC | 3142743 | 10 | 360 | 3123560 | MB-DLE 405 | 3/4" |
included |
|
11 | 3141886 | MBC 120 DLE | |||||||||
16 | 65 | 3141885 | MBC 65 DLE | 1/2" | |||||||
18 | 200 | 3123944 | MB-DLE 403 | ||||||||
TL | 3142744 | 10 | 360 | 3123560 | MB-DLE 405 | 3/4" |
included |
||||
11 | 3141886 | MBC 120 DLE | |||||||||
16 | 65 | 3141885 | MBC 65 DLE | 1/2" | |||||||
18 | 200 | 3123944 | MB-DLE 403 | ||||||||
MAX GAS 105P | 49 | 108 | TC | 3142745 | 16 | 360 | 3123560 | MB-DLE 405 | 3/4" | included | |
18 | 3141886 | MBC 120 DLE | |||||||||
34 | 65 | 3141885 | MBC 65 DLE | 1/2" | |||||||
36 | 200 | 3123944 | MB-DLE 403 | ||||||||
TL | 3142746 | 16 | 360 | 3123560 | MB-DLE 405 | 3/4" | included | ||||
18 | 3141886 | MBC 120 DLE | |||||||||
34 | 65 | 3141885 | MBC 65 DLE | 1/2" | |||||||
36 | 200 | 3123944 | MB-DLE 403 | ||||||||
MAX GAS 120P | 49 | 120 | TC | 3142747 | 16 | 360 | 3123560 | MB-DLE 405 | 3/4" | included | |
18 | 3141886 | MBC 120 DLE | |||||||||
34 | 65 | 3141885 | MBC 65 DLE | 1/2" | |||||||
36 | 200 | 3123944 | MB-DLE 403 | ||||||||
TL | 3142748 | 16 | 360 | 3123560 | MB-DLE 405 | 3/4" | included | ||||
18 | 3141886 | MBC 120 DLE | |||||||||
34 | 65 | 3141885 | MBC 65 DLE | 1/2" | |||||||
36 | 200 | 3123944 | MB-DLE 403 | ||||||||
MAX GAS 170P | 55 | 175 | TC | 3142749 | 13 | 360 | 3123947 | MB-DLE 410 | 1" | included | |
17 | 3123525 | MB-DLE 407 | 3/4" | ||||||||
6 | 3123560 | MB-DLE 405 | 3/4" | 3122300 | 30 | ||||||
TL | 3142750 | 13 | 360 | 3123947 | MB-DLE 410 | 1" | included | ||||
17 | 3123525 | MB-DLE 407 | 3/4" | ||||||||
26 | 3123560 | MB-DLE 405 | 3/4" | 3122300 | 1780 | ||||||
MAX GAS 250P | 55 | 240 | TC | 3142751 | 15 | 360 | 3141899 | MB-DLE 412 | 1"1/4 | included | |
17 | 3123947 | MB-DLE 410 | 1" | ||||||||
26 | 3123525 | MB-DLE 407 | 3/4" | ||||||||
40 | 3123560 | MB-DLE 405 | 3/4" | 3122300 | 30 | ||||||
TL | 3142752 | 15 | 360 | 3141899 | MB-DLE 412 | 1"1/4 | included | ||||
17 | 3123947 | MB-DLE 410 | 1" | ||||||||
26 | 3123525 | MB-DLE 407 | 3/4" | ||||||||
40 | 3123560 | MB-DLE 405 | 3/4" | 3122300 | 30 | ||||||
MAX GAS 350P |
100 | 350 | TC | 3142283 | 17 | 360 | 3142296 | MB-DLE 415 350/500 | 1"1/2 | included | |
20 | 3142295 | MB-DLE 412 350/500 | 1"1/4 | ||||||||
37 | 3142665 | MB-DLE 410 350/500 | 1" | ||||||||
60 | 3142392 | MB-DLE 407 350/500 | 3/4" | ||||||||
TL | 3142284 | 17 | 360 | 3142296 | MB-DLE 415 350/500 | 1"1/2 | included | ||||
20 | 3142295 | MB-DLE 412 350/500 | 1"1/4 | ||||||||
37 | 3142665 | MB-DLE 410 350/500 | 1" | ||||||||
60 | 3142392 | MB-DLE 407 350/500 | 3/4" | ||||||||
MAX GAS 500P |
120 | 500 | TC | 3142289 | 20 | 360 | 3142296 | MB-DLE 415 350/500 | 1"1/2 | included | |
35 | 3142295 | MB-DLE 412 350/500 | 1"1/4 | ||||||||
55 | 3142665 | MB-DLE 410 350/500 | 1" | ||||||||
90 | 3142392 | MB-DLE 407 350/500 | 3/4" | ||||||||
TL | 3142290 | 20 | 360 | 3142296 | MB-DLE 415 350/500 | 1"1/2 | included | ||||
35 | 3142295 | MB-DLE 412 350/500 | 1"1/4 | ||||||||
55 | 3142665 | MB-DLE 410 350/500 | 1" | ||||||||
90 | 3142392 | MB-DLE 407 350/500 | 3/4" |
Single Stage Class 3 Low NOx (NOx< 80 мг/кВтˑч) - исполнение с рампой VCS - TW
G eagles | Power, kWt] | Burner body | Gas pressure [mbar] | gas train |
Stab. pressure and filter |
|||||||
min | Max |
head |
the code | min | Max | the code | type | Ø | ||||
MAX GAS 170P | 55 | 175 | TC | 3142749 | 20 | 500 | 3141906 | VCS-125 | 1" | 3142521 | FGDR 1" | 100 |
TL | 3142750 | 20 | 500 | 3141906 | VCS-125 | 1" | 3142521 | FGDR 1" | 100 | |||
MAX GAS 250P | 55 | 240 | TC | 3142751 | 15 | 500 | 3142251 | VCS-240 | 1"1/2 | 3142523 | FGDR 1"1/2 | 200 |
34 | 3141906 | VCS-125 | 1" | 3142521 | FGDR 1" | 100 | ||||||
TL | 3142752 | 15 | 500 | 3142251 | VCS-240 | 1"1/2 | 3142523 | FGDR 1"1/2 | 200 | |||
34 | 3141906 | VCS-125 | 1" | 3142521 | FGDR 1" | 100 | ||||||
MAX GAS 350P | 100 | 350 | TC | 3142283 | 18 | 500 | 3142375 | VCS-240 350/500 | 1"1/2 | 3142523 | FGDR 1"1/2 | 200 |
54 | 3142374 | VCS-125 350/500 | 1" | 3142521 | FGDR 1" | 100 | ||||||
TL | 3142284 | 18 | 500 | 3142375 | VCS-240 350/500 | 1"1/2 | 3142523 | FGDR 1"1/2 | 200 | |||
54 | 3142374 | VCS-125 350/500 | 1" | 3142521 | FGDR 1" | 100 | ||||||
MAX GAS 500P | 120 | 500 | TC | 3142289 | 24 | 500 | 3142375 | VCS-240 350/500 | 1"1/2 | 3142523 | FGDR 1"1/2 | 200 |
98 | 3142374 | VCS-125 350/500 | 1" | 3142521 | FGDR 1" | 100 | ||||||
TL | 3142290 | 24 | 500 | 3142375 | VCS-240 350/500 | 1"1/2 | 3142523 | FGDR 1"1/2 | 200 | |||
98 | 3142374 | VCS-125 350/500 | 1" | 3142521 | FGDR 1" | 100 |
< 80 мг/кВт-ч)
G eagles | Power, kWt] | Burner body | Gas pressure [mbar] | gas train |
Stab. pressure and filter |
||||||
min | Max |
head |
the code | min | Max | the code | type | Ø | |||
MAX GAS 120 PAB | 40 | 120 | TC | 3123954 | 16 | 360 | 3123960 | MB-ZRDLE 405 | 3/4" | included | |
TL | 3123955 | 16 | 360 | 3123960 | MB-ZRDLE 405 | 3/4" | |||||
MAX GAS 170 PAB | 55 | 175 | TC | 3123956 | 13 | 360 | 3123962 | MB-ZRDLE 410 | 1" | included | |
17 | 3123961 | MB-ZRDLE 407 | 3/4" | ||||||||
26 | 3123960 | MB-ZRDLE 405 | 3/4" | 3122300 | 30 | ||||||
TL | 3123957 | 13 | 360 | 3123962 | MB-ZRDLE 410 | 1" | included | ||||
17 | 3123961 | MB-ZRDLE 407 | 3/4" | ||||||||
26 | 3123960 | MB-ZRDLE 405 | 3/4" | 3122300 | 30 | ||||||
MAX GAS 250 PAB | 55 | 240 | TC | 3123958 | 15 | 360 | 3141901 | MB-ZRDLE 412 | 1"1/4 | included | |
17 | 3123962 | MB-ZRDLE 410 | 1" | ||||||||
26 | 3123961 | MB-ZRDLE 407 | 3/4" | ||||||||
40 | 3123960 | MB-ZRDLE 405 | 3/4" | 3122300 | 30 | ||||||
TL | 3123959 | 15 | 360 | 3141901 | MB-ZRDLE 412 | 1"1/4 | included | ||||
17 | 3123962 | MB-ZRDLE 410 | 1" | ||||||||
26 | 3123961 | MB-ZRDLE 407 | 3/4" | ||||||||
40 | 3123960 | MB-ZRDLE 405 | 3/4" | 3122300 | 30 | ||||||
MAX GAS 350 PAB | 100 | 350 | TC | 3142285 | 17 | 360 | 3142296 | MB-DLE 415 350/500 | 1"1/2 | included | |
20 | 3142295 | MB-DLE 412 350/500 | 1"1/4 | ||||||||
37 | 3142665 | MB-DLE 410 350/500 | 1" | ||||||||
60 | 3142392 | MB-DLE 407 350/500 | 3/4" | ||||||||
TL | 3142286 | 17 | 360 | 3142296 | MB-DLE 415 350/500 | 1"1/2 | included | ||||
20 | 3142295 | MB-DLE 412 350/500 | 1"1/4 | ||||||||
37 | 3142665 | MB-DLE 410 350/500 | 1" | ||||||||
60 | 3142392 | MB-DLE 407 350/500 | 3/4" | ||||||||
MAX GAS 500 PAB | 120 | 500 | TC | 3142291 | 20 | 360 | 3142296 | MB-DLE 415 350/500 | 1"1/2 | included | |
35 | 3142295 | MB-DLE 412 350/500 | 1"1/4 | ||||||||
55 | 3142665 | MB-DLE 410 350/500 | 1" | ||||||||
90 | 3142392 | MB-DLE 407 350/500 | 3/4" | ||||||||
TL | 3142292 | 20 | 360 | 3142296 | MB-DLE 415 350/500 | 1"1/2 | included | ||||
35 | 3142295 | MB-DLE 412 350/500 | 1"1/4 | ||||||||
55 | 3142665 | MB-DLE 410 350/500 | 1" | ||||||||
90 | 3142392 | MB-DLE 407 350/500 | 3/4" |